Programmable Ampere Hour Meter

Programmable Ampere Hour Meter
Programmable Ampere Hour Meter
Product Code : 803AH
Product Description

We are a reputed manufacturer and trader of a huge gamut of Programmable Amp Hr Meter. Manufactured keeping in mind all the set quality norms of the industry, our range of meter is ideal for ensuring electroplating thickness by presetting AMP-HOUR. Also, our range of meter is widely useful for checking Amp-Hour of rechargeable batteries using voltage limit. Also, before the final dispatch., our range of Programmable Amp Hr Meter is well tested on different quality parameters by our quality experts.

Model code:803AH

Product Name:Programmable Amp Hr Meter

Category:ampere_hour_meters

Sub Category:battery_testing_application

Features

Separate displays for Voltage, Current and Amp-Hour

Programmable for AH/0.1AH/Amin/0.1AMin

Usable with any shunt by setting ‘Calibration’ for Amp-75mV

Calibration factor lockable from rear

4 Digit Amp-Hour and 6 Digit cumulative Amp-Hour display

Attractive front panel membrane switches in rugged Aluminum cabinet

In case of power failure, the current status of selected parameters, the current Amp-Hour and Cumulative Amp-Hour is saved

Specification

Display :All of 0.56in character height Red 7 Segment displays

a.3 Digits to display voltage 0 – 99.9V

b.4 Digits to display current 0 – 999.9Amps

c.6 Digits to display Amp-Hour (4 Digit) and cumulative Amp-Hour (6 Digit)

Max. Shunt : Max. value of 999.9 Amps corresponding to 75mV. User programmable from front in ‘CAL’ mode. (Max. value of 9999Amps also available on request)

Selection of Amp Hour/Min : Short Pin 17-18 for Amp-Hour

Open link of Pin 17-18 for Amp-Minute

0.1AH/Amin : Higher 0.1 resolution by shifting internal jumper by opening cover

Totaliser : 6 Digit readable in ‘Total’ Mode

Limit Up to 9999 Ahr/Amin settable in limit mode using increment/decrement switches

Relay : NO-P-NC of 5 Amp at 220V AC contact rating

Start : Pressing front panel switch or momentarily shorting rear Pins 5 & 6 by wiring an external switch

Memory :Non-volatile EEPROM solid state memory

Stores programmed value of shunt, preset value, current Amp-Hr and the current

Cumulative Amp-Hr to preserve current status on power failure

Lock : Open Link between Pin 1 & 2 to Lock ‘Cal’ i.e. shunt value

Low Voltage Stop Internally set at 10.5V for testing 12V battery. Short Pins 3 & 4 for this function

Supply : 220V AC ± 10% at 50/60Hz

Size : Vertical type with front panel 96 x 192 mm

Terminals : At rear with marking for wiring

Mounting : Panel Mounted

Fuse : At rear of 0.2Amps




COUNTRONICS